Document
Flyer-GC5-EN
Contenu du document
GC5
Ultra-sensitive compound specific isotope analysis
Extreme durability
High data quality
Low cost of ownership
High sensitivity
GC5
Generating a deeper
understanding with GC-IRMS
KEY FEATURES
• Market-leading sensitivity with
picomolar detection levels as
standard
• Powerful lyticOS
® Peak Mapping
reduces data processing time
of complex chromatograms to
minutes rather than hours,
generating a large increase in
lab productivity
• Outstanding robustness – low
maintenance, with long-life
reactor design
• 1500 °C furnace design
• Complete solvent peak removal
with 100% of analyte to
combustion furnace
C om bus tio n
C
om po und
S epa ra tio n R
em ove
i nt erfe renc es
A ut osa m ple r
C om bus tio n Tub e
Fu rn ace
Is o to pe R atio
D ete cto r
The GC5 is the answer for all those who wish
to enhance their research by investigating
compound speci-c stable isotope data. The
measurement of individual components in
complex mixtures allows for a wide variety
of applications to be pursued. Whether cor -
relating seizures of narcotics, authentication
of natural 1avor components or understand-
ing the origin of complex petroleum samples
- the GC5 can give you the answer you are
looking for. The need for compound speci-c
isotope analysis is widely acknowledged to
be able to answer complex questions where
a bulk analysis does not provide the answer.
The many features of the GC5 allow you to be
at the forefront in answering these questions.
AGILENT TECHNOLOGIES 8890 GC
As a global VAR partner of Agilent
Technologies, we offer Agilent‘s flagship
Gas Chromatograph 8890 with our IRMS
systems. The class-leading 8890 GC
offers the use of all the possibilities of the
Agilent catalogue. Equipped with a
standard split/splitless injector and Flame
Ionisation Detector, it is fully prepared
for IRMS measurements. The 8890 GC is
equipped with cost-saving advanced
electronic pneumatic controllers that
dramatically reduce the amount of helium
used by the GC. Using the Agilent Inert Flow
Path technology ensures the inertness of
every surface that touches your sample, so
you can achieve isotope analysis with the
lowest possible memory.
MICROBORE REACTOR TECHNOLOGY
Microbore reactor technology enables the
reactor to maintain peak shape and
chromatographic integrety during the
combustion stage, allowing the measure-
ment of two neighbouring peaks without
influencing each others isotope ratio.
The careful design of the catalyst-column
interface, avoiding small diameter
fragile ceramic reactors, makes for robust,
long-life microbore reactors. The element
specific design of the reactors enables the
measurement of even the most challenging
samples with temperatures up to 1500 °C.
Outstanding sample -exibility
The modular Agilent 8890 GC system lets you choose from
the industry?s widest selection of inlets, detectors, columns,
and automated sample introduction techniques, making the
measurement of a diverse range of sample concentrations
down to ppb level possible. Let it be SPME, headspace,
pyrolysis, capillary fiow technology, multi-dimensional GC,
the system is designed to handle these requirements easily.
With the demand in multi-isotope data ever increasing, such
as C & H in petroleum, N of amino acids, C, H & O in -avor and
fragrance substances, fast and incredibly simple switching of
modes is a real bene1t. With dedicated set-ups for your isotope
of interest, the GC5 interface has the answer to all possible
problems during the conversion process. Application speci1c
solutions for elements such as hydrogen or carbon make it
easier then before to achieve impressive results. With solutions
for fi
13C, fi 15N, fi 18O and fiD measurements, the GC5 is truely a
versatile instrument.
Add the power of quantitative and qualitative GC-MS analysis
to your system, providing single injection isotope ratio data
and structural con-rmation at the same time. Together with
our partner, Agilent Technologies, this allows the user to have
supreme con-dence in the quality of the data, even under
the most severe scrutiny.
Get more data from your analysis
Thanks to the placing of the open split to the IRMS inside the
furnace tube, the GC5 achieves class leading peak shapes and
sensitivity in compound speci-c isotope ratio analysis. In-line
removal of interfering components combined with the highest
possible transfer from the combustion interface to the IRMS,
make it the system of choice for those who want extreme
accuracy, the highest possible sensitivity and perfect linearity
in the most challenging of samples.
High performance as standard
One instrument for multiple isotopes
Elementar Analysensysteme GmbH
Elementar-Straße 1 · 63505 Langenselbold (Germany)
Phone: +49 (0) 6184 9393-0 | info@elementar.com | www.elementar.com
GC-IRMS analysis has never been easier!
EASE OF USE
The GC5 is optimized to significantly
simplify the daily routine operation.
Clearly arranged, easily accessible system
components minimize maintenance efforts.
The standard connectors and large O.D.
reactor tubes ensure a reliably leak-tight
instrument at any time . Thus customers
can enjoy smooth analyses and confidence
in their results.
lytic OS
lyticOS is the most intuitive analytical
software ever created. With the increasing
demand on the modern-day laboratory
for ever more efficiency, the overhead of
processing and evaluating large data sets
is an unwelcome requirement. lyticOS
removes these demands saving the analyst
time and money while generating data
more consistently.
IDEAL SOLUTION FOR
• Anti-doping laboratories
• Academic research groups
• Quality control laboratories
• Contract laboratories
SAMPLE TYPES ANALYZED
• Doping samples
• Plant, soil & sediment extracts
• Flavor and fragrance substances
• Petroleum products
• Lipids and Biomarkers
Art.-No. 05 005 183, 06?/?2021 A
Remarkable robustness and
longevity thanks to state-of-
the-art technology.
Outstanding precision and accu-
racy through high performance
combustion and pyrolysis with
matrix-independent results
through novel calibration strategy.
Class leading sensitivity
through world class interface
design. Low consumables consumption
and maintenance effort thanks to
straightforward design.
High sensitivity
N-ALKANE ? 13C
(‰ VPDB) St. Dev
(‰, 1%YTf& )
C-17 -31.00± 0.1
C-18 -31.01± 0.1
C-19 -33.00± 0.15
C-20 -32.19± 0.11
AMINO ACID ? 15N
(‰ VPDB) St. Dev
(‰, 1%YTf& )
L eucine 8.74± 0.18
A spartic Acid -1.53± 0.14
Glutamic acid -2.96± 0 13
P henylalanine -2.13± 0.13
N-ALKANE ?
D
(‰ VSMOW) St. Dev
(‰, 1%YTf& )
C-17 -141.25± 1.1
C-18 -53.48± 1.6
C-19 -120.68± 0.8
C-20 -48.21± 1.0
VANILLIN ? 18O
(‰ VSMOW) St. Dev
(‰, 1%YTf& )
A -1.36± 0.49
B 10.64± 0.31
C 14.00± 0.35
D 10.64± 0.21
Low cost of ownership
High data quality
Extreme durability
Elementar – your partner for excellent elemental analysis
Elementar is the world leader in high performance analysis of organic and inorganic elements.
Continuous innovation, creative solutions and comprehensive support form the foundation of the Elementar
brand, ensuring our products continue to advance science across agriculture, chemical, environmental,
energy, materials and forensics markets in more than 80 countries.
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
mercredi 10 novembre 2021