Document
Flyer-iso-FLOW-GHG-EN
Contenu du document
iso FLOW GHG
High performance sample preparation system
for trace greenhouse gas isotope analysis
High sensitivity High data quality
Great flexibility
Ease of use
Market leading isoprime precisION
stable isotope analyzer iso FLOW GHG sample preparation system
with autosampler
A powerful combination.
Greenhouse gases in the atmosphere are
major drivers for climate change and so it is
essential that we uncover the complex cycling
mechanisms of these gases throughout the
natural world. At the same time, we must seek
to understand the anthropogenic contribution
of these gases so that we can develop
successful strategies to mitigate and counter-
act humankind‘s damaging impact on the
careful balances in the natural world. Isotopic analysis of atmospheric greenhouse gases (GHGs)
is a critical tool in climate research thanks to the ability for
isotopic analysis to elucidate the origin of a sample.
The iso FLOW GHG is a fully automated, continuous flow
preparation system for the isotopic analysis of greenhouse
gases originating from a range of sample matrices and
is a key tool in the fight against climate change. Trace
concentrations of CO
2, N 2O and CH 4 in atmospheric samples
are measured using cryogenic pre-concentration, gas
chromatography and chemical traps to deliver the highest
precision isotopic analysis.
iso FLOW GHG
High precision analysis of
greenhouse gases
The analysis of your precious samples using the
iso FLOW GHG is made substantially simpler thanks to the
complete automation of the instrument. Using electronic
flow and pressure controllers to precisely deliver gases and
control sample flows throughout the system, all of which are
under control from lyticOS
® software leads to significantly
reduced operator contact time. Automated system checks,
leak checking and system configuration changes makes the
instrument easier to run for operators with diverse levels of
experience.
Complete automation
Flexible sample handling
Extend your ?
15N analysis further
iso FLOW GHG KEY FEATURES
• Capacity for up to 2 capillary GC columns
with a maximum temperature of 300 °C
• Automated control of all parameters driven
by modern lyticOS
® software
• Reduced consumption of laboratory
resources with sleep?/?wake-up functionality
• Flexible sample handling options for
multiple sample types
• Dual-core needle for analysis of dissolved
nitrate and gas samples from septum
sealed vials
• Optional 1,500 °C high temperature furnace
• Optional N
2?/?N2O simultaneous analysis
• Optional autosampler with capacity for up
to 220 samples
• Optional automated LN
2 dispenser for
extended analytical run times
INNOVATIVE CAPABILITIES
iso FLOW GHG can accommodate up
to two 30 m capillary GC columns in a
thermocouple-controlled heated oven
with a maximum temperature of 300 °C
allowing new possibilities for enhanced
GC chromatographic techniques. As well
as this, the optional combustion furnace
can operate at temperatures up to 1,500 °C
allowing researchers to explore alternative
furnace chemistries and target novel
isotope species.
Atmospheric trace greenhouse gas analysis is performed
using 100 ml, ?ow-through sample ?asks. For high
throughput analysis of gases and the determination
of dissolved nitrate samples presented in septum-
sealed vials the instrument can be equipped with an
autosampler compatible with multiple sample vial types
with up to 220 x 12 ml sample vials or 70 x 20 ml sample
vials. A manual injector port is also optionally available
for direct injections of gases into the iso FLOW GHG .
The iso FLOW GHG o?ers multiple opportunities to further
your analysis. When performing
15N and 18O isotope analysis
of atmospheric N
2O, the system can optionally also measure
15N of N 2 atmospheric gas from a single sample vial or fiask.
The isoprime precisION isotope ratio mass spectrometer
can also be optionally conflgured with a dedicated Faraday
collector array for the site-speciflc isotope analysis of
15N
of N
2O for better understanding of the biological pathways
responsible for the production of N
2O.
Elementar Analysensysteme GmbH
Elementar-Straße 1 · 63505 Langenselbold (Germany)
Phone: +49 (0) 6184 9393-0 | info@elementar.com | www.elementar.com
Art.-No. 05 005 763, 04?/?2021 A
High sensitivity High data quality
Great flexibility
Analyze trace
greenhouse gases
with the highest degree
of confidence. A modular system
ensures the
instrument is right
for you. Achieve the highest
analytical performance
with the most precise
instrument available. Complete automation
of every parameter
makes operation
very simple.
Ease of use
Source apportionment of GHGs
CARBON DIOXIDE
The atmospheric concentration of CO 2 has rapidly
increased over the past 250 years and is currently over
400 ppm. Isotopic analysis tells us this increase is due
to the burning of fossil fuels which are depleted in ?
13C.
Isotopic analysis also elucidates the terrestrial biosphere
sink of atmospheric CO
2 allowing us to understand how
the earth may respond to future atmospheric CO
2 forcing.
NITROUS OXIDE
Nitrous oxide concentration is very low in the
atmosphere (~330 ppb) but it has almost 300x the
warming potential of CO
2. Thanks to isotope analysis,
we know that approximately 75?% of N
2O atmospheric
emissions originate from agricultural activities and the
technique is crucial to further our understanding of
other mechanisms at play in the global N
2O cycle.
N20 N 2 CO2 CH 4
Height (nA)?¹?N ?¹?OHeight (nA) ?¹?NHeight (nA) ?¹³C?¹?O Height (nA) ?¹³C
AIR SAMPLE 01 2.88-9.39-19.33 2.68-0.53 20.15-14.18-2.85 2.41-40.60
AIR SAMPLE 02 3.15-9.93-19.50 2.7 3-0.52 20.52-14.16-2.90 2.12-40.99
AIR SAMPLE 03 3.08-9.84-19.47 2.7 1-0.56 20.48-14.23-2.86 2.23-40.53
AIR SAMPLE 04 3.13-9.11-19.40 2.7 3-0.56 20.07-14.20-2.90 2.39-40.91
AIR SAMPLE 05 3.19-9.78-19.56 2.74-0.56 20.31-14.19-2.88 2.44-41.41
AVERAGE 3.09-9.61-19.45 2.7 2-0.55 20.31-14.19-2.88 2.32-40.89
ST.DEV (1 ?) 0.12 0.350.09 0.020.020.20 0.030.02 0.14 0.35
Elementar – your partner for excellent elemental analysis
Elementar is the world leader in high performance analysis of organic and inorganic elements.
Continuous innovation, creative solutions and comprehensive support form the foundation of the Elementar
brand, ensuring our products continue to advance science across agriculture, chemical, environmental,
energy, materials and forensics markets in more than 80 countries.
METHANE
Atmospheric methane concentrations have been
increasing rapidly since 2007 but the reasons for this
increase are not clear. We do not know the extent of
methane trapped in permafrost or possibly released
from wetlands and wildfires. These phenomena have
the capacity to form run away feedback loops as further
warming increases atmospheric emissions. Coupled with
increased production of natural gas due to “fracking“,
these sources must be apportioned and isotope analysis
is an essential tool to achieve a fuller understanding of
the global CH
4 cycle.
The iso FLOW GHG sample preparation system provides
a fully automated, high performance, compact bench
top solution for the isotopic analysis of these trace
greenhouse gases.
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
mercredi 10 novembre 2021